Holland Particle Therapy Center
Hospital / health systemDelft, The Netherlands
Research output, citation impact, and the most-cited recent papers from Holland Particle Therapy Center. Aggregated across the NobleBlocks index of 300M+ scholarly works.
Top-cited papers from Holland Particle Therapy Center
OBJECTIVE:: We want to explore the safety and technical feasibility of MRI-guided stereotactic radiotherapy for locally advanced pancreatic cancer. METHODS:: A custom-made abdominal corset was manufactured to reduce breathing induced tumour motion. Delineation of the tumour and organs at risk (OARs) was performed on CT and multiparametric MRI. Tumour motion was quantified with cine MRI. After treatment planning, the static dose distribution was convolved with the cine MRI-based motion trajectory to simulate the delivered dose to the tumour and OARs. Stereotactic body radiation therapy (SBRT) was carried out up to a dose of 24 G in three fractions in 1 week. RESULTS:: From July 2013 to January 2016, 20 patients were included. Tumours and OARs were clearly visible with contrast-enhanced CT and MRI. After simulation of the delivered dose taking the motion into account, an adequate target coverage was achieved with acceptable dose in the OARs. No Grade3 or higher treatment related toxicity was observed. CONCLUSION:: MRI-guided SBRT for pancreatic cancer is technical feasible and safe, with no treatment related grade ≥3 toxicity. New strategies are applied, including an individual corset to reduce breathing motion, MRI-based delineation and simulation of motion-integrated dose distributions. ADVANCES IN KNOWLEDGE:: This article is the first to describe an MRI-integrated workflow in SBRT for locally advanced pancreatic cancer. In addition, it demonstrated that SBRT with an abdominal corset to reduce tumour motion is feasible and safe. TRIAL REGISTRATION:: This trial was registered at www.clinicaltrials.gov (NCT01898741) on July 9, 2013.
Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models and detector resolution effects. The results indicate that range shifts of [Formula: see text] can be detected at relatively low proton intensities ([Formula: see text] protons/spot) when spatial information obtained through imaging of both particle species are used simultaneously. This study lays the foundation for multi-particle detection and imaging systems in the context of range verification in PT.
Background and Purpose: Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension measurement of uveal melanoma. However, the lack of definitions of the 3D measurements of these tumour dimensions hinders further adaptation of MRI in ocular radiotherapy planning. In this study, we composed 3D MR-based definitions of tumour prominence and basal diameter and compared them to conventional ultrasound. Materials and methods: Tumours were delineated on 3DT2 and contrast-enhanced 3DT1 (T1gd) MRI for 25 patients. 3D definitions of tumour prominence and diameter were composed and evaluated automatically on the T1gd and T2 contours. Automatic T1gd measurements were compared to manual MRI measurements, to automatic T2 measurements and to manual ultrasound measurements. Results: Prominence measurements were similar for all modalities (median absolute difference 0.3 mm). Automatic T1gd diameter measurements were generally larger than manual MRI, automatic T2 and manual ultrasound measurements (median absolute differences of 0.5, 1.6 and 1.1 mm respectively), mainly due to difficulty defining the axis of the largest diameter. Largest differences between ultrasound and MRI for both prominence and diameter were found in anteriorly located tumours (up to 1.6 and 4.5 mm respectively), for which the tumour extent could not entirely be visualized with ultrasound. Conclusions: The proposed 3D definitions for tumour prominence and diameter agreed well with ultrasound measurements for tumours for which the extent was visible on ultrasound. 3D MRI measurements generally provided larger diameter measurements than ultrasound. In anteriorly located tumours, the MRI measurements were considered more accurate than conventional ultrasound.
Samenvatting Seminoma testis wordt gekenmerkt door een hoge ziektevrije en algehele overleving. Bij beperkt lymfogeen gemetastaseerde ziekte is para-aortale en para-iliacale radiotherapie een curatieve behandeloptie. Het belangrijkste nadeel van deze behandeling is het verhoogde risico op secundaire maligniteiten nadien. Dit lijkt voornamelijk te gelden voor tumoren van de maag, pancreas, nieren en blaas. Het risico op tumorinductie is afhankelijk van de bestralingsdosis die op het orgaan komt. Met protonentherapie is het mogelijk om de dosis op deze organen te verminderen ten opzichte van fotonentherapie. Vanaf maart 2022 wordt deze behandeling aangeboden in de drie Nederlandse protonencentra. Dit artikel beschrijft de indicaties en onderbouwing voor het gebruik van protonentherapie bij patiënten met een seminoom. Daarnaast worden enkele technische aspecten besproken.