Institute of Micro and Nanotechnology
facilityTres Cantos, Spain
Research output, citation impact, and the most-cited recent papers from Institute of Micro and Nanotechnology (Spain). Aggregated across the NobleBlocks index of 300M+ scholarly works.
Top-cited papers from Institute of Micro and Nanotechnology
Over the past several decades, there has been an ever-increasing demand for organ transplants. However, there is a severe shortage of donor organs, and as a result of the increasing demand, the gap between supply and demand continues to widen. A potential solution to this problem is to grow or fabricate organs using biomaterial scaffolds and a person's own cells. Although the realization of this solution has been limited, the development of new biofabrication approaches has made it more realistic. This review provides an overview of natural and synthetic biomaterials that have been used for organ/tissue development. It then discusses past and current biofabrication techniques, with a brief explanation of the state of the art. Finally, the review highlights the need for combining vascularization strategies with current biofabrication techniques. Given the multitude of applications of biofabrication technologies, from organ/tissue development to drug discovery/screening to development of complex in vitro models of human diseases, these manufacturing technologies can have a significant impact on the future of medicine and health care.
We present an overview of the main techniques for production and processing of graphene and related materials (GRMs), as well as the key characterization procedures. We adopt a 'hands-on' approach, providing practical details and procedures as derived from literature as well as from the authors' experience, in order to enable the reader to reproduce the results.
Determining the growth patterns of single cells offers answers to some of the most elusive questions in contemporary cell biology: how cell growth is regulated and how cell size distributions are maintained. For example, a linear growth in time implies that there is no regulation required to maintain homeostasis; an exponential pattern indicates the opposite. Recently, there has been great effort to measure single cells using microelectromechanical systems technology, and several important questions have been explored. However, a unified, easy-to-use methodology to measure the growth rate of individual adherent cells of various sizes has been lacking. Here we demonstrate that a newly developed optical interferometric technique, known as spatial light interference microscopy, can measure the cell dry mass of many individual adherent cells in various conditions, over spatial scales from micrometers to millimeters, temporal scales ranging from seconds to days, and cell types ranging from bacteria to mammalian cells. We found evidence of exponential growth in Escherichia coli, which agrees very well with other recent reports. Perhaps most importantly, combining spatial light interference microscopy with fluorescence imaging provides a unique method for studying cell cycle-dependent growth. Thus, by using a fluorescent reporter for the S phase, we measured single cell growth over each phase of the cell cycle in human osteosarcoma U2OS cells and found that the G2 phase exhibits the highest growth rate, which is mass-dependent and can be approximated by an exponential.
Magnesium coated by different transition metals (TM: Ti, Nb, V, Co, Mo, or Ni) with a grain size in the nano-scale formed a core (Mg)–shell (TM) like structure which can catalyse dehydrogenation.
Identification of energy-dissipation processes at the nanoscale is demonstrated by using amplitude-modulation atomic force microscopy. The variation of the energy dissipated on a surface by a vibrating tip as a function of its oscillation amplitude has a shape that singles out the dissipative process occurring at the surface. The method is illustrated by calculating the energy-dissipation curves for surface energy hysteresis, long-range interfacial interactions and viscoelasticity. The method remains valid with independency of the amount of dissipated energy per cycle, from 0.1 to 50 eV. The agreement obtained between theory and experiments performed on silicon and polystyrene validates the method.
The critical review discusses instrumental developments in single particle ICP-MS (spICP-MS) of recent years step-by-step. Nanoanalysis application papers from the literature are summarized in a tabular form including important experimental parameters.
Abstract Exploiting the excellent electronic properties of two-dimensional (2D) materials to fabricate advanced electronic circuits is a major goal for the semiconductor industry 1,2 . However, most studies in this field have been limited to the fabrication and characterization of isolated large (more than 1 µm 2 ) devices on unfunctional SiO 2 –Si substrates. Some studies have integrated monolayer graphene on silicon microchips as a large-area (more than 500 µm 2 ) interconnection 3 and as a channel of large transistors (roughly 16.5 µm 2 ) (refs. 4,5 ), but in all cases the integration density was low, no computation was demonstrated and manipulating monolayer 2D materials was challenging because native pinholes and cracks during transfer increase variability and reduce yield. Here, we present the fabrication of high-integration-density 2D–CMOS hybrid microchips for memristive applications—CMOS stands for complementary metal–oxide–semiconductor. We transfer a sheet of multilayer hexagonal boron nitride onto the back-end-of-line interconnections of silicon microchips containing CMOS transistors of the 180 nm node, and finalize the circuits by patterning the top electrodes and interconnections. The CMOS transistors provide outstanding control over the currents across the hexagonal boron nitride memristors, which allows us to achieve endurances of roughly 5 million cycles in memristors as small as 0.053 µm 2 . We demonstrate in-memory computation by constructing logic gates, and measure spike-timing dependent plasticity signals that are suitable for the implementation of spiking neural networks. The high performance and the relatively-high technology readiness level achieved represent a notable advance towards the integration of 2D materials in microelectronic products and memristive applications.
Fluorescent carbon dots (CDs) with a size smaller than 10 nm, excellent biocompatibility, and low to no cytotoxicity are considered as a rising star in nanomedicine. In this report, for the first time we demonstrate that green-emitting CDs with a carboxyl-rich surface can be employed as a trackable drug delivery agent for localized cancer treatment in a mouse model. The CDs are conjugated with the cancer drug, Doxorubicin (DOX), via non-covalent bonding, utilizing the native carboxyl groups on CDs and the amine moiety on DOX molecules. The pH difference between cancer and normal cells was successfully exploited as the triggering mechanism for DOX release. Our in vivo study demonstrated that the fluorescent CDs can serve as a targeted drug delivery system for localized therapy, and the stimuli-responsive non-covalent bonding between the nanodot carrier and the drug molecule is sufficiently stable in complex biological systems. Taken together, our work provides a strategy to promote the potential clinical application of CDs in cancer theranostics.
Free-standing single crystalline semiconductor membranes have gained intensive attention over the last few years due to their versatile usage in many applications.
Anodic porous alumina, -AAO- (also known as nanoporous alumina, nanohole alumina arrays, -NAA- or nanoporous anodized alumina platforms, -NAAP-) has opened new opportunities in a wide range of fields, and is used as an advanced photonic structure for applications in structural coloration and advanced optical biosensing based on the ordered nanoporous structure obtained and as a template to grow nanowires or nanotubes of different materials giving rise to metamaterials with tailored properties. Therefore, understanding the structure of nanoporous anodic alumina templates and knowing how they are fabricated provide a tool for the further design of structures based on them, such as 3D nanoporous structures developed recently. In this work, we review the latest developments related to nanoporous alumina, which is currently a very active field, to provide a solid and thorough reference for all interested experts, both in academia and industry, on these nanostructured and highly useful structures. We present an overview of theories on the formation of pores and self-ordering in alumina, paying special attention to those presented in recent years, and different nanostructures that have been developed recently. Therefore, a wide variety of architectures, ranging from ordered nanoporous structures to diameter changing pores, branched pores, and 3D nanostructures will be discussed. Next, some of the most relevant results using different nanostructured morphologies as templates for the growth of different materials with novel properties and reduced dimensionality in magnetism, thermoelectricity, etc. will be summarised, showing how these structures have influenced the state of the art in a wide variety of fields. Finally, a review on how these anodic aluminium membranes are used as platforms for different applications combined with optical techniques, together with principles behind these applications will be presented, in addition to a hint on the future applications of these versatile nanomaterials. In summary, this review is focused on the most recent developments, without neglecting the basis and older studies that have led the way to these findings. Thus, it gives an updated state-of-the-art review that should be useful not only for experts in the field, but also for non-specialists, helping them to gain a broad understanding of the importance of anodic porous alumina, and most probably, endow them with new ideas for its use in fields of interest or even developing the anodization technique.
In recent years, spin-orbit effects have been widely used to produce and detect spin currents in spintronic devices. The peculiar symmetry of the spin Hall effect allows creation of a spin accumulation at the interface between a metal with strong spin-orbit interaction and a magnetic insulator, which can lead to a net pure spin current flowing from the metal into the insulator. This spin current applies a torque on the magnetization, which can eventually be driven into steady motion. Tailoring this experiment on extended films has proven to be elusive, probably due to mode competition. This requires the reduction of both the thickness and lateral size to reach full damping compensation. Here we show clear evidence of coherent spin-orbit torque-induced auto-oscillation in micron-sized yttrium iron garnet discs of thickness 20 nm. Our results emphasize the key role of quasi-degenerate spin-wave modes, which increase the threshold current.
A nanostructure composed of Au/Co/Au nanodisks is fabricated. The behaviour of this system is completely different to that of a continuous Au/Co/Au layer. There is a relative enhancement of the Kerr rotation and ellipticity, as well as a strong dependence on the particle size. The origin of these properties is the plasmonlike structure that is supported by the nanosandwiches.
Slightly hydrogenated white TiO<sub>2</sub> nanoparticles show enhanced photocatalytic performance due to their increased surface defects, while gray or black H-TiO<sub>2</sub> nanoparticles display much worse catalytic performances due to the formation of bulk defects.
Nearly all underwater vehicles and surface ships today use sonar and vision for imaging and navigation. However, sonar and vision systems face various limitations, e.g., sonar blind zones, dark or murky environments, etc. Evolved over millions of years, fish use the lateral line, a distributed linear array of flow sensing organs, for underwater hydrodynamic imaging and information extraction. We demonstrate here a proof-of-concept artificial lateral line system. It enables a distant touch hydrodynamic imaging capability to critically augment sonar and vision systems. We show that the artificial lateral line can successfully perform dipole source localization and hydrodynamic wake detection. The development of the artificial lateral line is aimed at fundamentally enhancing human ability to detect, navigate, and survive in the underwater environment.
Liquid biopsy is a new diagnostic concept that provides important information for monitoring and identifying tumor genomes in body fluid samples. Detection of tumor origin biomolecules like circulating tumor cells (CTCs), circulating tumor specific nucleic acids (circulating tumor DNA (ctDNA), circulating tumor RNA (ctRNA), microRNAs (miRNAs), long non-coding RNAs (lnRNAs)), exosomes, autoantibodies in blood, saliva, stool, urine, etc. enables cancer screening, early stage diagnosis and evaluation of therapy response through minimally invasive means. From reliance on painful and hazardous tissue biopsies or imaging depending on sophisticated equipment, cancer management schemes are witnessing a rapid evolution towards minimally invasive yet highly sensitive liquid biopsy-based tools. Clinical application of liquid biopsy is already paving the way for precision theranostics and personalized medicine. This is achieved especially by enabling repeated sampling, which in turn provides a more comprehensive molecular profile of tumors. On the other hand, integration with novel miniaturized platforms, engineered nanomaterials, as well as electrochemical detection has led to the development of low-cost and simple platforms suited for point-of-care applications. Herein, we provide a comprehensive overview of the biogenesis, significance and potential role of four widely known biomarkers (CTCs, ctDNA, miRNA and exosomes) in cancer diagnostics and therapeutics. Furthermore, we provide a detailed discussion of the inherent biological and technical challenges associated with currently available methods and the possible pathways to overcome these challenges. The recent advances in the application of a wide range of nanomaterials in detecting these biomarkers are also highlighted.
The characterization of physical properties of cells such as their mass and stiffness has been of great interest and can have profound implications in cell biology, tissue engineering, cancer, and disease research. For example, the direct dependence of cell growth rate on cell mass for individual adherent human cells can elucidate the mechanisms underlying cell cycle progression. Here we develop an array of micro-electro-mechanical systems (MEMS) resonant mass sensors that can be used to directly measure the biophysical properties, mass, and growth rate of single adherent cells. Unlike conventional cantilever mass sensors, our sensors retain a uniform mass sensitivity over the cell attachment surface. By measuring the frequency shift of the mass sensors with growing (soft) cells and fixed (stiff) cells, and through analytical modeling, we derive the Young's modulus of the unfixed cell and unravel the dependence of the cell mass measurement on cell stiffness. Finally, we grew individual cells on the mass sensors and measured their mass for 50+ hours. Our results demonstrate that adherent human colon epithelial cells have increased growth rates with a larger cell mass, and the average growth rate increases linearly with the cell mass, at 3.25%/hr. Our sensitive mass sensors with a position-independent mass sensitivity can be coupled with microscopy for simultaneous monitoring of cell growth and status, and provide an ideal method to study cell growth, cell cycle progression, differentiation, and apoptosis.
Abstract This review article gives an overview of the recent research directions in eco‐friendly, non‐toxic, and earth‐abundant thermoelectric materials. It covers materials such as sulfides, tetrahedrites, earth‐abundant oxides, silicides, copper iodine, Half‐Heusler intermetallic compounds, nitrides, and other environmentally friendly thermoelectrics. In all cases, their history, structure, general characteristics, thermoelectric properties, synthesis methods, and related thermoelectric applications are compiled. It is also shown that they are starting to be an excellent alternative for producing cost‐effective, sustainable, and non‐toxic thermoelectric generators. This review does not try to include all possible materials, but to show that there are high zT thermoelectric materials that are starting to be an excellent alternative for producing cost‐effective, sustainable, and non‐toxic thermoelectric generators.
Hyaluronic acid (HA)-based biomaterials have been explored for a number of applications in biomedical engineering, particularly as tissue regeneration scaffolds. Crosslinked forms of HA are more robust and provide tunable mechanical properties and degradation rates that are critical in regenerative medicine; however, crosslinking modalities reported in the literature vary and there are few comparisons of different scaffold properties for various crosslinking approaches. In this study, we offer direct comparison of two methacrylation techniques for HA (glycidyl methacrylate HA [GMHA] or methacrylic anhydride HA [MAHA]). The two methods for methacrylating HA provide degrees of methacrylation ranging from 2.4 to 86%, reflecting a wider range of properties than is possible using only a single methacrylation technique. We have also characterized mechanical properties for nine different tissues isolated from rat (ranging from lung at the softest to muscle at the stiffest) using indentation techniques and show that we can match the full range of mechanical properties (0.35-6.13 kPa) using either GMHA or MAHA. To illustrate utility for neural tissue engineering applications, functional hydrogels with adhesive proteins (either GMHA or MAHA base hydrogels with collagen I and laminin) were designed with effective moduli mechanically matched to rat sciatic nerve (2.47 ± 0.31 kPa). We demonstrated ability of these hydrogels to support three-dimensional axonal elongation from dorsal root ganglia cultures. Overall, we have shown that methacrylated HA provides a tunable platform with a wide range of properties for use in soft tissue engineering.
We directly image hot spot formation in functioning mono- and bilayer graphene field effect transistors (GFETs) using infrared thermal microscopy. Correlating with an electrical-thermal transport model provides insight into carrier distributions, fields, and GFET power dissipation. The hot spot corresponds to the location of minimum charge density along the GFET; by changing the applied bias, this can be shifted between electrodes or held in the middle of the channel in ambipolar transport. Interestingly, the hot spot shape bears the imprint of the density of states in mono- vs bilayer graphene. More broadly, we find that thermal imaging combined with self-consistent simulation provide a noninvasive approach for more deeply examining transport and energy dissipation in nanoscale devices.
Seaweed biomass derived three-dimensional (3D) nanoaerogels demonstrate excellent bifunctionality for oxygen reduction and evolution reactions, showing high performance and cycling durability in zinc–air batteries.