Research indexJournal article
surface electromyographic data simulation
Reza, Farahi
Figshare1 Jan 2016Open access
NobleIDark:/48914/w1/20260526/10399F5ADOI10.6084/m9.figshare.4212123.v2
surface electromyographic data simulation
Reza, Farahi · Figshare · 2016
NobleIDark:/48914/w1/20260526/10399F5ADOI10.6084/m9.figshare.4212123.v2
Free to read at the publisher
You can read the abstract here, or the full text at the publisher.
Abstract
The model proposed by Farina et al was used to generate surface EMG signals [1]. In this model, the volume conductor was described as an anisotropic multilayered cylinder and the source was a spatio-temporal function describing the generation, propagation, and extinction of the intracellular action potential at the end-plate, along the fiber, and at the tendons, respectively. The Inter-Electrode-Distance (IED) was set to 5 mm as recommended in [2] to locate IZs. The remainder of the model parameters used in our study were in principle the same as those used by Mesin et al [3]. Finally, the number of active MUs in each 60-ms simulated signal interval was between 1 and 5. Signals were zero-phase digitally band-pass filtered [4] using an overall eighth-order Butterworth filter with cut-off frequencies 20 and 500 Hz. For each MU number category (1 to 5), sEMG signals with SNR values of -5, 0, 5, 10 and 15 dB were simulated to include very low to moderate quality sEMG signals. Twenty Single-Differential (SD) channels were simulated along the muscle fiber direction and sampling frequency was 4096 Hz. Thirty frames (or images) with up to 5 IZs were simulated for each SNR value. The temporal location of the IZs was created randomly in each frame. The signal SNR for each simulated 60-ms epoch was defined as the RMS of the raw sEMG divided by the standard deviation of the added Gaussian noise, expressed in dB [5]. Thus, a total of 750 1-D linear array sEMG signals were simulated, considering five SNR values and maximum five MUs . We also provided the gold standard data for the IZ channels and CV values. 1. Farina D, Mesin L, Martina S, Merletti R. A surface EMG generation model with multilayer cylindrical description of the volume conductor. IEEE transactions on bio-medical engineering. 2004;51(3):415-26. doi: 10.1109/tbme.2003.820998. 2. Afsharipour B, Ullah K, Merletti R. Spatial Aliasing and EMG Amplitude in Time and Space: Simulated Action Potential Maps. In: Roa Romero ML, editor. XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013: MEDICON 2013, 25-28 September 2013, Seville, Spain. Cham: Springer International Publishing; 2014. p. 293-6. 3. Mesin L, Gazzoni M, Merletti R. Automatic localisation of innervation zones: A simulation study of the external anal sphincter. Journal of Electromyography and Kinesiology. 2009;19(6):e413-e21. doi: 10.1016/j.jelekin.2009.02.002. 4. Gustafsson F. Determining the initial states in forward-backward filtering. IEEE Transactions on Signal Processing. 1996;44(4):988-92. doi: 10.1109/78.492552. 5. Kay SM. Fundamentals of statistical signal processing. Englewood Cliffs, N.J.: Prentice-Hall PTR; 1993.