Research index
耐風性能に着目した送電用中空鋼管鉄塔の補強方法に関する研究
海老原, Ebihara, エビハラ and 12 others
Kyushu University Institutional Repository (QIR) (Kyushu University)15 Jul 2004Open access
耐風性能に着目した送電用中空鋼管鉄塔の補強方法に関する研究
海老原, Ebihara, エビハラ and 12 others · Kyushu University Institutional Repository (QIR) (Kyushu University) · 2004
Abstract
The parallel-member attachng is a useful measure to renforce steel-tube transmission towers against wind loads. In some cases, however, an original method of fixing the parallel members is not available. So the authors have developed new three devices: a reinforced band, an improved reinforced band and a double reinforced band to fix the parallel members. These devices make use of frictional stress of the band against the main posts of the steel-tube transmission tower. The compression-tensile tests of those reinforced members showed satisfactory validity of the parallel-member attachnent method by the double reinforced band. In addition, a wind tunnel test was conducted to confirm aerodynamic characteristics of the reinforced member by the parallel-member attaciment. The test results indicated that the drag factor of the reinforced member was less than 0.2 and was dependent on the wind direction.