This chapter discusses the application of Electrocoagulation (EC) for the treatment of wastewater. EC is a cost-effective and eco-friendly method that involves the electrochemical involvement of wastewater treatment. The traditional EC process utilized direct current (DC) to produce coagulants, however, this method was associated with several drawbacks such as deposition of non-conducting material on the anode and passivation limits. Alternating current (AC) has been found to be a highly effective method to overcome the limitations of DC in EC. The study examines the effect of various factors such as current density, applied potential, frequency of current, initial pH, initial conductivity of electrolyte, temperature, operational time, electrolyte composition, electrode material, and configuration on the efficiency of EC. The results reveal that the final pH of the treated water depends on the initial composition of the electrolyte in the wastewater. Under optimal conditions of 14.00 volts, 300 Hz AC, and 90 minutes, the Al-Al electrode system achieved a removal of 80% Ca2+ and 70% of Mg2+. The study also investigated other electrode configurations such as Al-Fe and Fe-Fe, and found that different efficiencies were achieved.