鋼材とコンクリートを繋ぐバーリングシアコネクタの応力伝達機構 : バーリングの応力伝達機構の分類と適正配置間隔

Published in Kyushu University Institutional Repository (QIR) (Kyushu University) • Jul 15, 2013
NobleIDNI5P08W24R54S37
Authors:
照久 田中
,
Teruhisa Tanaka
,
テルヒサ タナカ

Abstract

This paper provides the standard push-out test results and discusses the resistance behavior between the steel beam and the concrete slab using burring shear connectors. The following results have been obtained: it has been shown clearly the rate of resistance force (bearing, shearing and adhesion) ...